Loft conversion (Class B) under the Welsh rules
No permission needed
Likely permitted development, so no planning application
What to do next
To have it confirmed in writing, apply for a Lawful Development Certificate.
Conditions that apply (1)Matching materials.
- Exterior materials must, so far as practicable, match the existing house.(Class B.2(a))
Rule checks
All 9 rule checks passed
- Not in a protected areaNone recorded
- Added roof space ≤ 50m³18.1m³ vs 50m³ (semi/detached)
- Not above the existing ridgeNo
- Not on the front roof slopeNo
- Not on a side slope within 10.5m of a roadNo
- No balcony, platform or roof terraceNo
- ≥ 20cm from the eaves30cm
- Not a listed buildingNo listing recorded
- No Article 4 DirectionNone recorded
Was this right?
The most you can build
The most you can build without an application: dormer width 7.5m, 30.2m³ dormer volume.
Yours is 4.5m.
What your project will cost
Sign in, free, to see build costs at your region’s rates, the saving from doing some of the work yourself, an all-in budget, and whether it’s likely to add value to your home.
Building Regulations
Separate from planning, and needed whether or not you apply for permission. 4 things need action.
- GeneralBuilding Regulations approval requiredAction needed
Converting a loft into a room always needs Building Regulations approval.
- Part AStructural calculationsAction needed
New floor joists, steel beams and dormer framing need a structural engineer's calculations.
- Part BFire escape routeAction needed
A protected stair route to an exit (usually fire doors on habitable rooms) and mains-wired linked smoke alarms are required.
- Part KStair headroom
Allow 2m headroom over the new stair; loft conversions may reduce this to 1.9m at the centre and 1.8m at the side.
- Part LInsulation
The new roof, dormer walls and windows must meet current insulation standards.
- Party WallParty Wall noticeAction needed
Steel beams bearing into a shared wall need notice under the Party Wall etc. Act 1996.
Your neighbours
Under the Party Wall etc. Act 1996 you must give your neighbours written notice before this work.
Party structure notice (section 3, at least 2 months’s notice)
Loft conversions usually cut into the shared wall to bear steel beams, and a hip-to-gable may raise it.
PlanItClear is free while we launch. If it saved you a fee, you can support us.
Support PlanItClearPlanItClear is a screening tool, not legal advice. Check with your council, or get a Lawful Development Certificate, before you build. Costs are rough ranges. Data sources and licences. Report a problem with this result.
Which rules are checked
In England, the GPDO 2015 Schedule 2, Part 1 Classes A to E and Part 14 Class A, as amended to 27 August 2026. In Wales, the GPDO 1995 as it applies in Wales, Part 1 Classes A to E and Part 40 Class A. In Scotland, the GPDO (Scotland) 1992, Part 1 Classes 1A to 3A and Part 1A Class 6HA. In Northern Ireland, the GPDO (NI) 2015, Part 1 Classes A to D and Part 2 Classes A and B.